Strona 1 - User's Manual

QSCLP-100Four Channel Low Profile RS-232 Asynchronous Communications Adapterfor PCI busUser's ManualQUATECH, INC. TEL: (330) 434-3154662 Wolf Led

Strona 2 - 1 General Information

4.4.2 Clock Rate MultiplierA standard RS-232 serial port operates at a clock speed of 1.8432 MHz. Inorder to achieve higher data rates, Quatech Enhan

Strona 3 - 2 Hardware Configuration

5 Windows Configurations5.1 Windows Millennium 1. After inserting the QSCLP- 100 for the first time the "Add New HardwareWizard" will

Strona 4

5.2 Windows 20001. After inserting a QSCLP-100 for the first time, the "Add New HardwareWizard will appear at start up. Click the "OK"

Strona 5 - 3 Hardware Installation

5.3 Windows 981. After inserting a QSCLP-100 for the first time, the "Add New HardwareWizard will appear at start up. Click the "Next"

Strona 6

4. The following dialog box will display the appropriate INF file on the diskette in drive. Click the "Next" button. 5. Window will c

Strona 7

PCI communications adapter before, the dialog box may simply indicate that ithas found a "PCI Card."2. Select the radio button for "Dri

Strona 8 - 4.3 Interrupt Status Register

The following instructions provide step-by-step instructions on viewingresources used by the QSCLP-100 in Windows 95 using the "Device Manager&qu

Strona 9 - 4.4 Options Register

Figure 13--- Windows 95 Device Manager6. The QSCLP-100 serial ports are also listed under the group Ports (COM andLPT). Windows 95 does not assign CO

Strona 10 - 4.4.2 Clock Rate Multiplier

Figure 14 --- Windows 95 Device Manager9. Use the Logical COM Port names to access the serial ports on yourQSCLP-100 through your software application

Strona 11 - 5 Windows Configurations

6 Other Operating SystemsDevice drivers for Windows NT and OS/2 are also available for theQSCLP-100. The board can be used under DOS and other operat

Strona 12 - 5.2 Windows 2000

1 General InformationThe Quatech, Inc. QSCLP-100 provides four RS-232 asynchronous serialcommunication interfaces for Low Profile IBM-compatible perso

Strona 13 - 5.3 Windows 98

Quatech's "QTPCI" utility supplies the information required when modifying theserial port settings of the application. This program sh

Strona 14 - 5.4 Windows 95

with more details such as the Vendor and Device IDs, PCI Class Code, size of memoryand I/O regions, etc. Pressing the "N" key will show sim

Strona 15

7 External ConnectionsRS-232-C devices are classified by their function as either Data TerminalEquipment (DTE) or Data Communication Equipment (DCE).

Strona 16

The QSCLP-100 is a DTE device which connects to peripheral equipmentthrough a single female D-44 connector, or using the adapter cable, four male D-9c

Strona 17

4800430033001570800115.2200016301100900330230.41100900670430100460.8470430300100N/A921.625%transtime20%transtime15%transtime10% transtime4% transtimeM

Strona 18

10 TroubleshootingListed here are some common problems and frequent causes of thoseproblems. If the information here does not provide a solution, con

Strona 19 - 6 Other Operating Systems

WARRANTY INFORMATIONQuatech, Inc. warrants the QSCLP-100 to be free of defects for five (5) years from the date of purchase. Quatech, Inc. wi

Strona 20

Declaration of ConformityManufacturer's Name: Quatech Inc.Manufacturer's Address: 662 Wolf Ledges ParkwayAkron, Ohio 44311 (USA)Application

Strona 21

Table of Contents2810 Troubleshooting...269 Specifications...258 PCI R

Strona 22 - 7 External Connections

? 2002, Quatech, Inc.NOTICEThe information contained in this document cannot be reproduced in any formwithout the written consent of Quatech, Inc. L

Strona 23

2 Hardware ConfigurationThe QSCLP-100 is automatically configured at boot time by the computer'sBIOS or operating system. There are no required

Strona 24

8 PCI Resource MapListed below are the PCI resources used by the QSCLP-100. Suchinformation may be of use to customers writing their own device drive

Strona 25 - 10 Troubleshooting

9 SpecificationsBus interface: PCI, 32-bit bus, 5-volt onlyIBM-compatible computersDimensions: approx. 5.0" x 3.7"Serial portsController: 16

Strona 26

QSCLP-100 User's Manual Revision 1.00January 2002P/N: 940-0180-100

Strona 27 - Declaration of Conformity

These jumpers force an increase of the UART input clock frequency by a factorof two, four, or eight. This feature can allow legacy software to use ba

Strona 28

3 Hardware Installation1. Turn off the power of the computer system in which the QSCLP-100 is to beinstalled.2. Remove the system cover according to t

Strona 29

(This page intentionally blank.)QSCLP-100 User's Manual 5

Strona 30 - 8 PCI Resource Map

4 Address Map and Special RegistersThis chapter explains how the four UARTs and special registers are addressed,as well as the layout of those registe

Strona 31 - 9 Specifications

4.2 Enabling the Special RegistersThe QSCLP-100 contains two unique registers, an Interrupt Status Registerand an Options Register. These registers a

Strona 32 - P/N: 940-0180-100

4.4 Options RegisterThe Options Register allows software to identify the QSCLP-100 as a QuatechEnhanced Serial Adapter. It also allows software to se