Quatech DSP-100 Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Quatech DSP-100. Quatech DSP-100 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - User's Manual

DSP-100Dual Channel RS-232 PCMCIAAsynchronous Adapterfor PCMCIA Card Standard compatible machinesUser's ManualQUATECH, INC. TEL: (330) 434-315466

Strona 2

2.1 DSP-100 Client Driver for DOSIn order to use the DSP-100 Client Driver, the system must be configured with Card andSocket Services software. Card

Strona 3 - Warranty Information

7. Reboot the system and note the message displayed when the DSP-100 ClientDriver is loaded. If the Client Driver reports an "invalid command li

Strona 4 - Declaration of Conformity

U instructs the Client Driver to disable the DSP-100's interrupt status registerand enable the Scratchpad registers of the individual UARTs. Thi

Strona 5 - Table of Contents

2.1.2.3 Example 3DEVICE = C:\DSP-100\DSP100CL.SYS (s0,b300,i5)In example 3, a single command line argument is provided. The Client Driver willattemp

Strona 6

2.1.2.6 Example 6DEVICE = C:\DSP-100\DSP100CL.SYS (b300,i5) ( ) (i10)In example 6, the three command line arguments of example 5 have been rearranged

Strona 7 - 1. Introduction

2.1.3 Common ProblemsGeneric Client Drivers:Many Card and Socket Services packages include a generic client driver (orSuperClient) which configures st

Strona 8 - DSP-100 User's Manual 2

2.2 DSP-100 Enabler for DOSFor systems that are not operating PCMCIA Card and Socket Services software, theDSP-100 DOS Enabler may be used to enable a

Strona 9

2.2.1 Command Line OptionsTo configure a DSP-100 in the system, the Enabler requires one command lineargument from the user to determine the configura

Strona 10 - IMPORTANT:

R instructs the Enabler to release the resources previously allocated to theDSP-100. When the 'R' option is used, any settings specified by

Strona 11 - 2.1.2 Command Line Options

2.2.1.4 Example 4DSP100EN.EXE (s0,b300,i3,wd8)In example 4, the Enabler will configure the DSP-100 in socket 0 with a base address of300H and IRQ 3 u

Strona 12

(This page intentionally left blank.)

Strona 13

2.2.2 Common ProblemsMemory Range Exclusion:The Enabler requires a region of high DOS memory when configuring a DSP-100. Thisregion is 1000H bytes (4

Strona 14

3. Windows 95 InstallationTo allow easy configuration of the DSP-100, an Windows 95 "INF" configuration filehas been written for the hardw

Strona 15 - 2.1.3 Common Problems

3.2 DSP-100 Resource Settings in Windows 95Windows 95 maintains a registry of all known hardware installed within the computer.Inside this hardware re

Strona 16 - 2.2 DSP-100 Enabler for DOS

6. View the Properties dialog for each COM port and examine the Resourcesallocated to each port. Inside the Resource allocation window two of theCOM

Strona 17 - 2.2.1 Command Line Options

3.2.2 Changing Resource Settings with Device ManagerThe DSP-100's serial ports are addressable in two modes: block mode, and “COM”mode (see Chap

Strona 18 - DSP100EN.EXE (i10,u,b340,s1)

6. Select a Basic Configurations that displays "No conflicts" in the bottomdisplay region titled Conflicting Device List from the drop down

Strona 19 - DSP100EN.EXE (s1,r,wcc)

8. To modify the Interrupt Request setting click the resource name and clickthe Change Setting button. An Edit Resource window will open up. Insidet

Strona 20 - 2.2.2 Common Problems

4. Windows 98/Millennium (ME) InstallationTo allow easy configuration of the DSP-100, an Windows 98/ME "INF" configurationfile has been

Strona 21 - 3. Windows 95 Installation

4.2 DSP-100 Resource Settings in Windows 98/MEWindows 98/ME maintains a registry of all known hardware installed within thecomputer. Inside this hard

Strona 22

6. View the Properties dialog for each COM port and examine the Resourcesallocated to each port. Inside the Resource allocation window two of theCOM

Strona 23

Warranty InformationQuatech Inc. warrants the DSP-100 to be free of defects for five (5) year from the date ofpurchase. Quatech Inc. w

Strona 24

4.2.2 Changing Resource Settings with Device ManagerThe DSP-100's serial ports are addressable in two modes: block mode, and “COM”mode (see Chap

Strona 25

6. Select a Basic Configurations that displays "No conflicts" in the bottomdisplay region titled Conflicting Device List from the drop down

Strona 26

8. To modify the Interrupt Request setting click the resource name and clickthe Change Setting button. An Edit Resource window will open up. Insidet

Strona 27

5. Windows 2000 InstallationTo allow easy configuration of the DSP-100, an Windows 2000 "INF" configuration filehas been written for the

Strona 28

5.2 DSP-100 Resource Settings in Windows 2000Windows 2000 maintains a registry of all known hardware installed within thecomputer. Inside this hardwa

Strona 29

Windows 2000 Device Manager5.2.2 Changing Resource Settings with Device ManagerThe DSP-100's serial ports are addressable in two modes: block mo

Strona 30

4. Open the Properties dialog for the DSP-100 device, then click the Resourcestab to view the Input/Output Range and Interrupt Request resourceallocat

Strona 31

7. To modify the Interrupt Request setting click the resource name and clickthe Change Setting button. An Edit Resource window will open up. Insidet

Strona 32

6 Windows NT6.1 Installing DSP-100 Under Windows NTTo allow easy configuration of the DSP-100 the Quatech Device Manager for WindowsNT has been writ

Strona 33

1. Locate and double click the Quatech Device Manager icon on the desktopDevice Manager Icon on DesktopDSP-100 User's Manual 33

Strona 34

Declaration of ConformityManufacturer's Name: Quatech Inc.Manufacturer's Address: 662 Wolf Ledges ParkwayAkron, OH 44311 (USA)Application of

Strona 35

2. Click the ‘Add’ button at the bottom of the Quatech Device ManagerWindow.3. Follow the steps for the ‘Add Quatech Hardware Wizard’.DSP-100 User&apo

Strona 36

4. Complete the final steps of the installation, insert the PCMCIA Card andreboot the computer.v Additional help is available onlineThe DSP-100 PC Car

Strona 37

7 Windows CEThe Quatech PCMCIA Windows CD installation copies a multiple device-specific .cab files and theini file to your desktop computer and laun

Strona 38 - 6 Windows NT

3. The setup program will copy the files to predetermined location, which can be changed by the user. Click next to proceed.. Installation is now comp

Strona 39 - DSP-100 User's Manual 33

8 OS/2 InstallationIn order to use the DSP-100 Client Driver for OS/2, the system must be configured asfollows:1. The system must be running OS/2 ver

Strona 40 - DSP-100 User's Manual 34

8.1 Command Line OptionsThe DSP-100 Client Driver for OS/2 supports two methods of configuration: using"system assigned" resources and usin

Strona 41

8.1.2 Configuring With "User Assigned" ResourcesAs mentioned in the previous section, allowing the OS/2 Plug-and-Play system toassign the ha

Strona 42 - 7 Windows CE

8.1.2.2 Example 2DEVICE=C:\DSP-100\DSP100.SYS (7,120,15) (3,300,4)In example 2, the Client Driver will attempt to configure the DSP-100 as COM3 and

Strona 43

8.2 Monitoring The Status Of PCMCIA CardsOS/2 Warp provides a utility called "Plug and Play for PCMCIA" that can be used tomonitor the statu

Strona 44 - 8 OS/2 Installation

Parameter Overlapping:When installing the DSP-100, each command line argument specifies the first of twoCOM ports. If these arguments overlap, the Cl

Strona 45 - 8.1 Command Line Options

Table of Contents4811 . External Connections ...4610 . Hardware Information ...

Strona 46

9. Unix SupportThe DSP-100 and other Quatech asynchronous serial communications interfaceproducts are supported in the UNIX operating system by Quat

Strona 47

(This page intentionally left blank.)DSP-100 User's Manual 45

Strona 48 - 8.3 Common Problems

10. Hardware InformationThe DSP-100's two asynchronous serial ports are implemented using 2 standard 16C550UARTs. Each of these UARTs requires

Strona 49

DSP-100 User's Manual 47

Strona 50 - 9. Unix Support

11. External ConnectionsAn adapter cable is included with the DSP-100 to convert the 25-pin output connectorinto 2 standard D-9 male RS-232 connector

Strona 51 - DSP-100 User's Manual 45

(This page intentionally left blank.)DSP-100 User's Manual 49

Strona 52 - 10. Hardware Information

12. SpecificationsBus Interface PCMCIA PC Card Standard 2.1 compliantPhysical Dimensions Type II PCMCIA card (5mm)Maximum Baud Rate 120KPower Require

Strona 53 - DSP-100 User's Manual 47

DSP-100User's ManualRevision 2.30September, 2001P/N 940-0088-230DSP-100 User's Manual 51

Strona 54 - 11. External Connections

5012 . Specifications ...

Strona 55 - DSP-100 User's Manual 49

1. IntroductionThe DSP-100 provides two independent RS-232 asynchronous serial communicationsinterfaces for systems equipped with PCMCIA Type II and/

Strona 56 - 12. Specifications

(This page intentionally left blank.)DSP-100 User's Manual 2

Strona 57

2. DOS / Windows 3.x InstallationTwo configuration software programs are provided with the DSP-100: a Client Driver,DSP100CL.SYS, and a card Enabler

Komentarze do niniejszej Instrukcji

Brak uwag