8 009 411/11-06-2001 SICK ⋅ AG ⋅ Auto Ident ⋅ Germany ⋅ All rights reserved 6/8
Instructions for the installation and operation of the QUATECH
PC serial high-speed interface card
5 Type of card and supplier
This card is commodity and modified for SICK:
Manufacturer: Fa. QUATECH
Description: DSC-200/ 300 Two Channel RS 422/485 Asynchronous Communica-
tions Adapter
SICK Material No.: 6 022 515
6 General description of the card/ Safety instructions
The card is a double serial interface card RS 422/485.
The output connection of the QUATEC Interface card for PCI Bus is
different to the connection of the MOXA Interface card for EISA
BUS. Please follow the instructions in section 7.3.
The card is provided with a 16 MHz-quartz by the supplier in order to obtain a max.
baud rate of 1 Mbaud.
This is necessary to operate the SICK laser scanners of the LMS 2XX series without an ad-
ditional evaluation unit. The max. baud rate of the scanners is 500 KBaud.
Back of the card:
7 Installation and set-up
7.1 Procedure
1. Turn off the PC
2. Set the jumpers/ switches and install the QUATECH card in any free ISA-slot
3. Turn on the PC
4. Configuration (
see section 7.2
)
Komentarze do niniejszej Instrukcji