8 009 411/11-06-2001 SICK ⋅ AG ⋅ Auto Ident ⋅ Germany ⋅ All rights reserved 8/8
Do not connect the unused pins.
QUATECH DSC200/300 LMS200/291 LMS 220/211/221
Signal Pin Signal Pin Pin
GND 3 GND 5 Shield
TxD+ 2 RxD+ 2 2
RxD+ 4 TxD+ 3 10
TxD- 7 RxD- 1 1
RxD- 8 TxD- 4 9
Linkage 7 3
Linkage 8 11
8 Operation of the card
8.1 Different baud rate divisors
The table shows the divisor which need to be used at the certain baud rate (if no SICK MST
software is used).
Baud rate Divisor Remarks
9 600 1 075 9 600 Baud
19 200 2 216 19 200 Baud
38 400 4 300 38 400 Baud
500 000 56 000 500 kBaud
8.2 Usage of LMSIBS User software
If you use the LMS/LMI user software, you have to define in the user software that a High-
Speed-interface card is used.
In the menu "sensor-interface" choose the card type “.../1MBd” in the field of "Baud
rate/card type”.
8.3 Usage of the MST200 Measurement Software Tool
If you use MST, you have to define in the user software that a High-Speed interface card is
used.
Enter "Card Type" = "2" in the configuration file.